CADWELD Molds for Cast Ground Plates, Receptacles & Studs Welded Electrical Connections
cadweld-molds-for-cast-ground-plates--receptacles
The castings are made from a copper alloy. CADWELD ground plate connections result in current carrying capacity equal to that of the conductor or stud and cannot loosen or corrode.
Caution: Use only CADWELD cast ground plates. Other similar plates may be available which do not meet the strength requirements necessary. They may crack or break during installation.
Use a CADWELD Type TA or Type SS mold when connecting the CADWELD cast ground plate to the ground conductor. The cast ground plate stud size noted above fits the mold opening for a cable of the same size. /Asset/a1293.jpg
Cast Ground Plate Connections Molds - B161/162/164
(18) Cast Ground Plate Connections To Structures- CADWELD cast ground plates used in concrete structures offer convenient ground system connection points. These ground points are used for equipment, machinery and structure grounding after completion of the concrete work.
- For structural reasons, cast ground plates should always be encased in concrete.
- For B-161-2Q, B-162-2Q or B-164-2Q Cast Ground Plates Only.
- Concentric stranded copper cable is listed.
Cadweld Cast Ground Plates
(5) CADWELD ground plates used in concrete structures offer convenient ground system connection points. These ground points are used for equipment, machinery and structure grounding after completion of the concrete work.The castings are made from a copper alloy. CADWELD ground plate connections result in current carrying capacity equal to that of the conductor or stud and cannot loosen or corrode.
Caution: Use only CADWELD cast ground plates. Other similar plates may be available which do not meet the strength requirements necessary. They may crack or break during installation.
Use a CADWELD Type TA or Type SS mold when connecting the CADWELD cast ground plate to the ground conductor. The cast ground plate stud size noted above fits the mold opening for a cable of the same size. /Asset/a1293.jpg
Aircraft Grounding Receptacles Connections Molds - RA/RB
(12) RA and RB Types for Aircraft Grounding- CADWELD connection is made with the receptacle in the inverted position. The resulting riser fits inside a 1/2" pipe for proper elevation locating
- Concentric stranded copper cable is listed.
Aircraft Grounding Receptacles - GB/GB-GR/GB-GT
(54)- CADWELD splices for Grounding Receptacles B165 and B165R to the top of ground rods with or without cable connection for most sizes and types of ground rods, including copperclad and stainless, stainless clad or galvanized steel.
- Concentric stranded copper cable is listed.
Copper and Steel Studs - HX/HV
(17)- Connections of copper or steel studs to steel surfaces. Copper studs on grounded structures provide a convenient point for attachment of temporary protective ground clamps.